• 1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet
  • 1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet
  • 1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet
1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet

1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet

Product Details:

Place of Origin: Shenzhen, China (Mainland)
Brand Name: ESTEL
Certification: ISO9001, CE, 3C, FCC, TLC, IP55
Model Number: ET7070155-1

Payment & Shipping Terms:

Minimum Order Quantity: 1 SET
Price: Negotiation
Packaging Details: Wooden case
Delivery Time: 20-30 working days
Payment Terms: L/C, D/A, D/P, T/T, MoneyGram
Supply Ability: 5,000 sets per month
Get Best Price Contact Now

Detail Information

Dimension: External Dimension W×D×H 700×700×1550mm Equipment Installation: 19” Standard Rack
Material: Galvanized Steel; Double Walls With Heat Insulation Between Two Walls. Cooling: 1200W Air Conditioner And Two Fans
Air Pressure: 62kpa ~ 101kpa (similar To 0m ~ 5000m Altitude) Relative Humidity: 5% ~ 100%
High Light:

1200W Outdoor Telecom Enclosure

,

Double Door Outdoor Telecom Enclosure

,

1200W weatherproof electrical cabinet

Product Description

1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet

 

1. Description Of IP55 Enclosure

 

IP55 Enclosure is suitable for the various environment including house electronic equipment, industrial process control, external plant, telecommunications equipment, food, and medical equipment, bespoke application and many more.IP55 enclosure provides complete protection against contact with live or moving parts inside the enclosure, thus add protection from water, up to water projected by a nozzle against enclosure from any direction.

 

2. Accessories Options Of The IP55 Enclosure

 

Fan kits

Cabinet insulation

Racks and shelving

Heating and cooling systems

Silk screening and digital printing

Custom locks, hinges and brackets

Lights, alarms and other electronics

 

3. Technical Parameters

 

Item Type Technical Parameter
Structure Dimension External Dimension W×D×H 700×700×1550mm
Layout One compartment
Equipment Installation Method 19” standard rack
Door Double Door, With one front door and one back door, totally two doors; with special lock for outdoor cabinet (support padlock)
Material Galvanized steel; double walls with heat insulation between two walls.
Structure Assembled
Ingress Protection IP55
Temperature Control Cooling 1200W Air Conditioner and two fans
Lighting LED lamp 48V LED lamp
Humidity Relative Humidity 5% ~ 100%
Pressure Air Pressure 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)

 

4. Accessories List

 

No. Item Quantity Unit Specs
1 Outdoor Telecom Cabinet 1 Set

(1) External Dimension W×D×H 700×700×1550mm

(2) Double Door With one front door and one back door, totally two doors; with special lock for outdoor cabinet (support padlock)

(3) Material: galvanized steel; double walls, with heat insulation between two walls.

2 Air Conditioner 1 Set 1200W Air Conditioner, AC220V power supply
3 110V To 220V Transformer 1 Set Used for air conditioner input
4 Fans 2 PC DC48V
5 Power Distribution Unit 1 Set

Grade B Lightning Proof

Height: 3U

6 Embedded Telecom Power System (UPS) 1 Set

DC48V, 90A, 4800W; Model:

GPE4890J

7 Package 1 Set Wooden Case
8 Sensor     Sensors (including 1 smoke sensor, 2 door alarm, 2 LED lamp, 1 water sensor, and 1 temperature and humidity sensor.)

 

5. Enclosure Cooling

 

1 Set 1200W Air Conditioner, AC220V power supply

Two DC48V fans.

 

6. Cabinet Structure

 

(1) External Dimension W×D×H 700×700×1550mm;

(2) One compartment;

(3) Material: galvanized steel; double walls,with heat insulation between two walls.

 

7. Cabinet Picture:

 

1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet 0

 

8. GPE4890J Embedded Power System Operating Principle

 

GPE4890J consists of distribution unit, rectifier module (up to 3 sets) and 1 monitoring module After AC power is controlled by the AC hydraulic switch and then through the EMI board lightning protection and filtering processing, into the rectifier module, AC hydraulic switch has the function of overload and short circuit protection to AC power. Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the system will be powered by the battery. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage is under -46.2V±0.5V, the monitoring module reports battery under voltage alarm signal; When the battery voltage is under -45.6V±0.5V, close LVLD load output; When the battery voltage is under -43.2V±0.5V, close LVBD load output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values that users can reset).

Want to Know more details about this product
I am interested in 1200W Outdoor Telecom Enclosure Double Door Weatherproof Electrical Cabinet could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.